CO2 Laser Markers C.0102/C.0302/ C.0602
(4.8)
SKU: N/AReliable, field-proven CO2 laser marking technology combined with unrivalled flexibility Wavelengths, scan head aperture, marking head position, IP rating, power and much more can be configured to suit your application needs. Flexibility is built-in. With print speeds up to 2,000 characters/sec. and line speeds up to 900 m/min., these marking lasers address both simple and complex code requirements on a range of substrates including paperboard, glass, painted metals and many plastic materials. This flexibility makes the C-Series lasers well suited for laser marking applications in various industries: for automotive parts, electronic components, plastic parts, cables, and many more. Marking your products on-the-fly or when stationary, with simple date codes or complex graphics, the C.0102 and C.0302 offer cost effective solutions to your part marking challenges. The C.0102 10-Watt offers all the performance features the C.0302 30-Watt marking laser provides, but with a power source better matched for moderate line speed applications or those at rest. The 30-Watt C.0302 is perfect for higher speed mark-on-the-fly applications (of up to 150,000 products/hour) or more demanding materials such as many plastics.
Key Features
- High-quality construction
- Professional grade
- Easy to use
- Reliable performance
| Marking features | ||||||
|---|---|---|---|---|---|---|
| Marking heads and focusing |
|
|||||
| Marking fields (mm2) | Depends on marking head and focus lens
|
|||||
| Laser | ||||||
| Type | Sealed CO2 laser, power class 10/30-Watt, Wavelengths 9.3 µm, 10.2 µm and 10.6 µm | |||||
| Laser class | 4 (as per IEC 60825-1) | |||||
| User interfaces | ||||||
| Handheld controller | ||||||
| PC Software | FOBA Draw, MarkUS 2.12 (as of Q2.2018) | |||||
| Smart Graph Com | ActiveX interface | |||||
| Interfaces |
|
|||||
| Integration | ||||||
|
||||||
| Supply | ||||||
| Electrical requirements | L/N/PE 100 – 240 VAC, 50/60 Hz | |||||
| Power consumption | C.0102: max. 0.4 kW, C.0302: max. 0.7 kW | |||||
| IP rating |
|
|||||
| Cooling | Air-cooled | |||||
| Temp./Humidity | 5-40°C/ 10-90%, non-condensing | |||||
| Weight | Marking unit C.0102 (IP54) ~13 kg Marking unit C.0302 (IP54) ~19.1 kg Supply unit (IP54) approx. ~11.5 kg | |||||
| Applicable Certifications | CE, TÜV, NRTL/FCC; RoHS compliant | |||||